Part Number ET74422 described as Circuit Breaker with NSN 5925-00-063-8997 with FSC 5925 Circuit Breakers by Manufacture Spd Electrical Systems Inc is available in stock. We provide comprehensive database of aerospace and aviation components, sub-assemblies, and completed assemblies allows us to respond to your RFQ within 15 minutes.
Simplified Purchasing is owned and operated by ASAP Semiconductor, an industry-leading AS9120B, ISO 9001:2015, and FAA AC 0056B certified distributor of Spd Electrical Systems Inc aerospace and aviation parts like ET74422. We are a service-oriented company that provides quality NSN components with an emphasis on United States export law through our delivery centers at 2 strategic locations, California and Nevada.
Please fill all fields in the RFQ form for ET74422. This will help us understand your requirements and ensure timely delivery. A dedicated product expert will contact you shortly.
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5925-00-063-8997 Item Description: CIRCUIT BREAKER | 5925 | 000638997 | 0 | P | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | A | 0 | ||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
ET74422 | 2 | 9 | 5 |
MRC | Criteria | Characteristic |
---|---|---|
AKPX | Pole Quantity | 3 |
CPLM | Maximum Continuous Load Current Rating Per Pole | 75.0 AMPERES AC AND 75.0 AMPERES DC ALL LOCATIONS |
AFJN | Fragility Factor | MODERATELY RUGGED |
BBRJ | Special Handling Feature | MAGNETIC |
CBBL | Features Provided | ADJUSTABLE TRIP RELEASE |
CPRG | Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps | 10000.0 AC AND 10000.0 DC ALL LOCATIONS |
CPRH | Circuit Protection Type | OVERCURRENT ALL LOCATIONS |
FREQ | Frequency In Hertz | 400.0 ALL LOCATIONS |
AXHR | Mounting Facility Type And Quantity | 4 UNTHREADED HOLE |
CPRL | Trip Release Characteristic | TIME DELAY ALL LOCATIONS |
CPRJ | Trip Release Method | THERMAL-MAGNETIC ALL LOCATIONS |
ABMK | Overall Width | 4.875 INCHES NOMINAL |
CPRQ | Reset Method | MANUAL |
CRCF | Trip Release Ambient Temp Rating | 50.0 DEG CELSIUS NOMINAL ALL LOCATIONS |
CPRR | Main Contact Tripping Mechanism Type | TRIP FREE |
CPRW | Actuator Function | TRIP-RESET |
CPSF | Adjustable Trip Setting Current Range Per Pole In Amps | +900.0/+1050.0 AC ALL LOCATIONS |
CPRT | Manual Actuator Type And Quantity | 1 TOGGLE |
ADTV | Case Material | PLASTIC |
ABHP | Overall Length | 6.500 INCHES NOMINAL |
AAQL | Body Style | |
ABKW | Overall Height | 4.125 INCHES NOMINAL |
MRC | Decoded Requirement | Clear Text Reply |
APNQ | Arc Quenching Method | AIR |
CPRF | Operating Voltage Type And Rating Per Pole In Volts | 500.0 AC AND 250.0 DC ALL LOCATIONS |
CQWN | Trip Delay Time In Seconds Per Rated Continuous Current | 20.000 MINIMUM AT 600 PCT AND 32.000 MAXIMUM AT 600 PCT ALL LOCATIONS |
CPRN | Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent | 145.0 ALL LOCATIONS |
AEBV | Unthreaded Mounting Hole Diameter | 0.190 INCHES NOMINAL |
CPRX | Actuator Position Designation | AT POLE TWO |
CQXF | Inclosure Protection Type For Which Designed | GENERAL PURPOSE |
TTQY | Terminal Type And Quantity | 6 QUICK DISCONNECT, FEMALE |