Part Number PP11-1-0.500A-0B-V described as Circuit Breaker with NSN 5925-01-575-6956 with FSC 5925 Circuit Breakers by Manufacture Sensata Technologies Inc is available in stock. We provide comprehensive database of aerospace and aviation components, sub-assemblies, and completed assemblies allows us to respond to your RFQ within 15 minutes.
Simplified Purchasing is owned and operated by ASAP Semiconductor, an industry-leading AS9120B, ISO 9001:2015, and FAA AC 0056B certified distributor of Sensata Technologies Inc aerospace and aviation parts like PP11-1-0.500A-0B-V. We are a service-oriented company that provides quality NSN components with an emphasis on United States export law through our delivery centers at 2 strategic locations, California and Nevada.
Please fill all fields in the RFQ form for PP11-1-0.500A-0B-V. This will help us understand your requirements and ensure timely delivery. A dedicated product expert will contact you shortly.
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5925-01-575-6956 Item Description: Circuit Breaker | 5925 | 015756956 | 0 | P | A | |
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | A | A | 0 | |||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
Pp11-1-0.500a-0b-V | 5 | 2 | 3 |
MRC | Criteria | Characteristic |
---|---|---|
CXCY | Part Name Assigned By Controlling Agency | CAGE: SNAPAK SERIES MAGNETIC CIRCUIT PROTECTOR |
AKPX | Pole Quantity | 1 |
FREQ | Frequency In Hertz | 50.0 ALL LOCATIONS OR 60.0 ALL LOCATIONS |
CPRG | Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps | 1000.0 DC ALL LOCATIONS |
CPRH | Circuit Protection Type | OVERCURRENT SINGLE LOCATION |
CPRJ | Trip Release Method | MAGNETIC SINGLE LOCATION |
CPRH | Circuit Protection Type | OVERCURRENT ALL LOCATIONS |
CPRL | Trip Release Characteristic | TIME DELAY SINGLE LOCATION |
CPRJ | Trip Release Method | MAGNETIC ALL LOCATIONS |
CPRN | Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent | 135.0 ALL LOCATIONS |
CPRQ | Reset Method | MANUAL |
CPRN | Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent | 135.0 SINGLE LOCATION |
ADAT | Body Width | 1.304 INCHES NOMINAL |
CPRT | Manual Actuator Type And Quantity | 1 PUSH-PULL |
AXHR | Mounting Facility Type And Quantity | 4 TERMINAL |
AGAV | End Item Identification | C-10256C/BRR-6 TRIDENT, CONTROL INDICATOR; C-10256D/BRR-6 TRIDENT, CONTROL INDICATOR; OHIO CLASS SSBN |
ADTV | Case Material | PLASTIC |
TTQY | Terminal Type And Quantity | 4 KNIFE BLADE |
MRC | Decoded Requirement | Clear Text Reply |
AAQL | Body Style | MULTIPOLE-SINGLE ACTUATOR TYPE |
ABHP | Overall Length | 1.375 NOMINAL INCHES |
CPRG | Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps | 1000.0 DC SINGLE LOCATION |
CQWN | Trip Delay Time In Seconds Per Rated Continuous Current | 1.000 MINIMUM AT 200 PCT ALL LOCATIONS AND 8.000 MAXIMUM AT 200 PCT ALL LOCATIONS |
CPRL | Trip Release Characteristic | TIME DELAY ALL LOCATIONS |
CPRR | Main Contact Tripping Mechanism Type | TRIP FREE |
Don’t forget That We offer Same-Day Shipping and 24/7 Service for Our Customers.