Part Number APL111125978-102 described as Circuit Breaker with NSN 5925-01-407-2542 with FSC 5925 Circuit Breakers by Manufacture Sensata Technologies Inc is available in stock. We provide comprehensive database of aerospace and aviation components, sub-assemblies, and completed assemblies allows us to respond to your RFQ within 15 minutes.
Simplified Purchasing is owned and operated by ASAP Semiconductor, an industry-leading AS9120B, ISO 9001:2015, and FAA AC 0056B certified distributor of Sensata Technologies Inc aerospace and aviation parts like APL111125978-102. We are a service-oriented company that provides quality NSN components with an emphasis on United States export law through our delivery centers at 2 strategic locations, California and Nevada.
Please fill all fields in the RFQ form for APL111125978-102. This will help us understand your requirements and ensure timely delivery. A dedicated product expert will contact you shortly.
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5925-01-407-2542 Item Description: Circuit Breaker | 5925 | 014072542 | 0 | P | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | A | |||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
Ielhk1111-25978-102-V | 5 | 2 | 5 |
MRC | Criteria | Characteristic |
---|---|---|
TTQY | Terminal Type And Quantity | 8 COMPRESSION |
MRC | Decoded Requirement | Clear Text Reply |
AEBY | Distance Between Centerlines Of Mounting Facilities Parallel To Body Length | 2.060 INCHES NOMINAL |
CPLM | Maximum Continuous Load Current Rating Per Pole | 40.0 AMPERES AC SECOND LOCATION |
CPLM | Maximum Continuous Load Current Rating Per Pole | 40.0 AMPERES AC THIRD LOCATION |
AJEC | Boss Height | 0.150 INCHES NOMINAL |
AKPX | Pole Quantity | 4 |
CPRF | Operating Voltage Type And Rating Per Pole In Volts | 240.0 AC THIRD LOCATION |
CPRF | Operating Voltage Type And Rating Per Pole In Volts | 240.0 AC FIRST LOCATION |
FREQ | Frequency In Hertz | 60.0 FIRST LOCATION |
CPRG | Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps | 1000.0 AC THIRD LOCATION |
CPRF | Operating Voltage Type And Rating Per Pole In Volts | 240.0 AC SECOND LOCATION |
CPRG | Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps | 1000.0 DC FIRST LOCATION |
CPRH | Circuit Protection Type | OVERCURRENT ALL LOCATIONS |
CPRG | Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps | 2000.0 DC FOURTH LOCATION |
FREQ | Frequency In Hertz | 60.0 SECOND LOCATION |
FREQ | Frequency In Hertz | 60.0 THIRD LOCATION |
CPRL | Trip Release Characteristic | TIME DELAY ALL LOCATIONS |
THSD | Thread Series Designator | UNC |
CPRN | Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent | 125.0 ALL LOCATIONS |
AEHA | Distance Between Centerlines Of Mounting Facilities Parallel To Body Width | 0.750 INCHES NOMINAL |
CPRR | Main Contact Tripping Mechanism Type | TRIP FREE |
CPRQ | Reset Method | MANUAL |
CPRW | Actuator Function | TRIP-RESET |
AXHR | Mounting Facility Type And Quantity | 8 THREADED HOLE |
ADAT | Body Width | 3.015 INCHES MAXIMUM |
CPSM | Internal Trip Release Configuration | SERIES TRIP ALL LOCATIONS |
CPRX | Actuator Position Designation | AT EACH POLE |
CPRY | External Actuator Linkage Arrangement | ONE, TWO, THREE, AND FOUR LINKED |
CQJX | Nominal Thread Size | 0.138 INCHES |
AJWX | Mounting Surface To Terminal End Distance | 2.645 INCHES NOMINAL |
ADTV | Case Material | PLASTIC |
ADAQ | Body Length | 2.530 INCHES MAXIMUM |
AEBP | Center To Center Distance Between Terminals Parallel To Length | 1.940 INCHES NOMINAL |
AAQL | Body Style | MULTIPOLE-MULTIPLE ACTUATOR TYPE |
CPLM | Maximum Continuous Load Current Rating Per Pole | 40.0 AMPERES AC FIRST LOCATION |
AEBQ | Center To Center Distance Between Terminals Parallel To Width | 0.750 INCHES NOMINAL |
CPRG | Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps | 1000.0 AC SECOND LOCATION |
CQWN | Trip Delay Time In Seconds Per Rated Continuous Current | 3.000 MINIMUM AT 200 PCT ALL LOCATIONS AND 20.000 MAXIMUM AT 200 PCT ALL LOCATIONS |
CPRJ | Trip Release Method | MAGNETIC ALL LOCATIONS |
CPRT | Manual Actuator Type And Quantity | 4 TOGGLE |