Part Number S-4764 described as Transformer Power with NSN 5950-01-100-5862 with FSC 5950 Coils and Transformers by Manufacture Grand Transformers Inc is available in stock. We provide comprehensive database of aerospace and aviation components, sub-assemblies, and completed assemblies allows us to respond to your RFQ within 15 minutes.
Simplified Purchasing is owned and operated by ASAP Semiconductor, an industry-leading AS9120B, ISO 9001:2015, and FAA AC 0056B certified distributor of Grand Transformers Inc aerospace and aviation parts like S-4764. We are a service-oriented company that provides quality NSN components with an emphasis on United States export law through our delivery centers at 2 strategic locations, California and Nevada.
Please fill all fields in the RFQ form for S-4764. This will help us understand your requirements and ensure timely delivery. A dedicated product expert will contact you shortly.
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5950-01-100-5862 Item Description: Transformer Power | 5950 | 011005862 | 0 | P | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | U | |||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
286024 | 5 | 2 | 3 |
MRC | Criteria | Characteristic |
---|---|---|
AARG | RELIABILITY INDICATOR | NOT ESTABLISHED |
ABHP | OVERALL LENGTH | 3.750 INCHES MAXIMUM |
ABTB | MOUNTING HOLE DIAMETER | 0.188 INCHES NOMINAL SINGLE GROUP |
ACZB | FREQUENCY RATING | 50.0 HERTZ MINIMUM SINGLE COMPONENT AND 400.0 HERTZ MAXIMUM SINGLE COMPONENT |
ACZC | INPUT-OUTPUT PHASE RELATIONSHIP | SINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT |
ACZX | WINDING SHIELDING METHOD | INTERNAL SHIELD GROUNDED TO INCLOSURE AND CORE SINGLE COMPONENT |
ADAQ | BODY LENGTH | 2.750 INCHES MAXIMUM |
ADAT | BODY WIDTH | 2.120 INCHES MAXIMUM |
ADAU | BODY HEIGHT | 2.280 INCHES MAXIMUM |
AEJN | DISTANCE BETWEEN MOUNTING FACILITY CENTERS | 3.120 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
AKNA | INCLOSURE TYPE | FULLY INCLOSED |
AKPV | MOUNTING FACILITY QUANTITY | 2 SINGLE GROUP |
AXGY | MOUNTING METHOD | FLANGE SINGLE GROUP AND UNTHREADED HOLE SINGLE GROUP |
BPLC | WINDING FUNCTION AND QUANTITY | 2 PRIMARY SINGLE COMPONENT AND 2 SECONDARY SINGLE COMPONENT |
CRBZ | WINDING OPERATING CURRENT | 0.53 AMPERES AC MAXIMUM SINGLE COMPONENT 1ST SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 11.70 AC POUNDS PER HOUR WET SINGLE COMPONENT 1ST SECONDARY |
TTQY | TERMINAL TYPE AND QUANTITY | 8 WIRE LEAD W-LUG |