Part Number 145HS287-2 described as Transducer Dual with NSN 1650-01-119-7368 with FSC 1650 Aircraft Hydraulic Vacuum and De icing System Components by Manufacture Curtiss Wright Corporation is available in stock. We provide comprehensive database of aerospace and aviation components, sub-assemblies, and completed assemblies allows us to respond to your RFQ within 15 minutes.
Simplified Purchasing is owned and operated by ASAP Semiconductor, an industry-leading AS9120B, ISO 9001:2015, and FAA AC 0056B certified distributor of Curtiss Wright Corporation aerospace and aviation parts like 145HS287-2. We are a service-oriented company that provides quality NSN components with an emphasis on United States export law through our delivery centers at 2 strategic locations, California and Nevada.
Please fill all fields in the RFQ form for 145HS287-2. This will help us understand your requirements and ensure timely delivery. A dedicated product expert will contact you shortly.
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
1650-01-119-7368 Item Description: Transducer Dual | 1650 | 011197368 | 0 | N | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | A | 0 | ||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
Q2403 | 5 | 2 | 3 |
MRC | Criteria | Characteristic |
---|---|---|
CRTL | CRITICALITY CODE JUSTIFICATION | FEAT |
CXCY | PART NAME ASSIGNED BY CONTROLLING AGENCY | TRANSDUCER ASSEMBLY DUAL LINEAR ILCA |
FEAT | SPECIAL FEATURES | CRITICAL APPLICATION ITEM |
FTLD | FUNCTIONAL DESCRIPTION | MOISTURE THE DESIGN CONFIGURATION SHALL BE SUCH THAT MOISTURE CANNOT COLLECT IN DEPRESSIONS OR IRREGULAR SURFACES TO THE EXTENT OF CAUSING MALFUNCTION FROM CORROSION FREEZING OR OTHER INJURIOUS EFFECTS VIBRATION AND SHOCK TRANSDUCER ASS |
SPCL | SPECIAL TEST FEATURES | MISSION RELIABILITY EACH TRANSDUCER SHALL HAVE NO LESS THAN .99999 PROBABILITY OF COMPLETING A 1 HOUR MISSION WITHOUT INCURRING A MISSION FAILURE |
SUPP | SUPPLEMENTARY FEATURES | CLEANING OF SAND AND DUST AIRBORNE SAND AND DUST PARTICLES ENCOUNTERED IN DESERT OPERATIONS PER METHOD 510 PROCEDURE I OF MIL-STD-810B SALT SPRAY ATMOSPHERE CONTAINING SALT LADEN MOISTURE PER METHOD 509 PROCEDURE I OF MIL-STD-810B |
TEXT | GENERAL CHARACTERISTICS ITEM DESCRIPTION | THE TRANSDUCER ASSEMBLY SHALL BE CAPABLE OF CONTINUOUS OPERATION THROUGHOUT THE AMBIENT TEMPERATURE RANGE OF-50 DEGREES FAHRENHEIT TO 275 DEGREES FAHRENHEIT UNIT SHALL BE CAPABLE OF OPERATION FROM SEA LEVEL TO 50 000 FEET ALTITUDE COMBI |
Don’t forget That We offer Same-Day Shipping and 24/7 Service for Our Customers.